Skip to main content

www.hksccm.org

2011 Mar – Accuracy of ultrasonography performed by critical care physicians for the diagnosis of DVT

Kory PD, Pellecchia CM, Shiloh AL, Mayo PH, DiBello C, Koenig S.;Chest. 2011 Mar;139(3):538-42. Epub 2010 Oct 28


BACKGROUND: DVT is common among critically ill patients. A rapid and accurate diagnosis is essential for patient care. We assessed the accuracy and timeliness of intensivist-performed compression ultrasonography studies (IP-CUS) for proximal lower extremity DVT (PLEDVT) by comparing results with the formal vascular study (FVS) performed by ultrasonography technicians and interpreted by radiologists.

METHODS: We conducted a multicenter, retrospective review of IP-CUS examinations performed in an ICU by pulmonary and critical care fellows and attending physicians. Patients suspected of having DVT underwent IP-CUS, using a standard two-dimensional compression ultrasonography protocol for the diagnosis of PLEDVT. The IP-CUS data were collected prospectively as part of a quality-improvement initiative. The IP-CUS interpretation was recorded and timed at the end of the examination on a standardized report form. An FVS was then ordered, and the FVS result was used as the criterion standard for calculating sensitivity and specificity. Time delays between the IP-CUS and FVS were recorded.

RESULTS: A total of 128 IP-CUS were compared with an FVS. Eighty-one percent of the IP-CUS were performed by fellows with <2 years of clinical ultrasonography experience. Prevalence of DVT was 20%. IP-CUS studies yielded a sensitivity of 86% and a specificity of 96% with a diagnostic accuracy of 95%. Median time delay between the ordering of FVS and the FVS result was 13.8 h.

CONCLUSIONS: Rapid and accurate diagnosis of proximal lower extremity DVT can be achieved by intensivists performing compression ultrasonography at the bedside

Weblink here